AIR VOLUME CONTROLINSTALLATION GUIDE

Simple Step-By-Step Installation

1Turn Off Power & Drain Tank

Blue water tank and connected supply piping
  • Turn off power at the breaker.
  • Close the house supply valve.
  • Drain the tank below the air volume control.

2Remove Existing Air Volume Control

Tank opening after removal of the old air volume control
  • Remove the old air volume control.
  • Remove the pressure gauge.
  • Clean the tank threads.

3Prepare New Air Volume Control

New air volume control with float arm and red float
  • Apply thread sealant.
  • Wrap threads with thread tape.
  • Install the pressure gauge into the new control if required.

Install the pressure gauge into the new air volume control BEFORE final installation.

4Install New Air Volume Control

Air volume control assembly being installed in the tank
  • Thread the assembly into the tank.
  • Tighten securely.
  • Position the gauge for easy viewing.

Do not overtighten.

5Restore Service

Water tank with installed control and pressure gauge
  • Restore power.
  • Allow the tank to refill.
  • Open the house supply valve.
Pump startsTank fillsPressure buildsPump stops

6Check for Leaks

Close-up of the installed pressure gauge and air volume control
  • Inspect all connections.
  • Verify pressure gauge operation.
  • Confirm normal pump operation.

Installation Complete

Your Merrill Air Volume Control is ready for service.

  • Maintains proper air volume
  • Helps prevent waterlogging
  • Consistent system pressure
  • Reliable operation