CHECK & FOOT VALVEINSTALLATION GUIDE

For Merrill check valves & screened foot valves

Keep water moving in the right direction.

Check valves prevent reverse flow. Foot valves help hold prime and screen debris.

Before You Start

Match the Valve to the System

Choose CHECK for approved pump-discharge locations or FOOT for a jet-pump suction inlet. Verify size, material, pressure rating and mounting orientation.

Gather Tools & Materials

Have pipe supports, matching fittings, approved thread sealant, two wrenches and pump instructions. Confirm existing check-valve locations.

5 Simple Steps

  1. Shut Off Power & Relieve Pressure

    Disconnect pump power; close or isolate the water line. Drain and verify zero pressure before cutting or removing a valve.

  2. Confirm Location & Flow Direction

    For CHECK, the flow arrow follows pump discharge toward the supply. For FOOT, water enters the screened end and flows toward the jet pump.

  3. Prepare & Connect the Pipe

    Clean threads and remove debris. Use approved sealant on male pipe threads and counterhold with a second wrench. Do not overtighten.

  4. Set the Valve in the Right Position

    Follow model-approved orientation. Keep a foot-valve screen submerged during pumping, well above bottom sediment; secure the suction line.

  5. Prime, Restore Flow & Test

    For jet pumps, fill and prime per the pump manual before starting. Inspect joints, verify flow and check for loss of prime, leaks or chatter.