E-5000 Series Parts Kit
EF Parts Kit · PKEF
Repair your yard hydrant from above ground.
What’s in the Kit

Packing Assembly
Parts shown in assembly order.

Repair the Hydrant Head

- Remove the handle bolt, handle and both draw straps. Mark the pivot position on the rod. Loosen the C-5 bolt and remove the pivot connector.
- Remove the packing nut. For a packing leak, add one-third of the new packing above the old packing. Leave old packing in place.
- Reinstall the packing nut and snug it. Refit the pivot at its mark and tighten the C-5 bolt. Reattach the draw straps, handle and bolt.
Replace the Plunger

- Wrap tape around the standpipe just below the head to mark its installed position.
- Hold the standpipe still with one pipe wrench. With a second wrench, turn the head counterclockwise. Lift the head and rod straight up.
- Unscrew the old plunger from the rod, gripping its metal base. Thread on the new one. Lower the rod and tighten the head back to the tape mark.
Adjust and Test
Packing leak? Snug the packing nut in small increments. Spout drips when closed? Shut off water, loosen C-5 and adjust the pivot to lower the plunger. Retighten the bolt.