Merrill E-5000 Series yard hydrant

E-5000 Series Parts Kit

EF Parts Kit · PKEF

Repair your yard hydrant from above ground.

What’s in the Kit

PKEF kit: packing gland C-31, valve stem packing C-35, packing nut C-30, plunger C-115, pivot connector B-25, stainless steel 1/4-inch hex head bolt C-5, draw straps G-20, and O-ring OR116

Packing Assembly

Parts shown in assembly order.

Packing assembly order: packing nut C-30, stem packing C-35, packing gland C-31, O-ring OR116

Repair the Hydrant Head

Hydrant head showing draw straps G-20, hex head bolt C-5, and packing gland C-31
  1. Remove the handle bolt, handle and both draw straps. Mark the pivot position on the rod. Loosen the C-5 bolt and remove the pivot connector.
  2. Remove the packing nut. For a packing leak, add one-third of the new packing above the old packing. Leave old packing in place.
  3. Reinstall the packing nut and snug it. Refit the pivot at its mark and tighten the C-5 bolt. Reattach the draw straps, handle and bolt.

Replace the Plunger

Plunger C-115 inside the buried hydrant valve
  1. Wrap tape around the standpipe just below the head to mark its installed position.
  2. Hold the standpipe still with one pipe wrench. With a second wrench, turn the head counterclockwise. Lift the head and rod straight up.
  3. Unscrew the old plunger from the rod, gripping its metal base. Thread on the new one. Lower the rod and tighten the head back to the tape mark.

Adjust and Test

Packing leak? Snug the packing nut in small increments. Spout drips when closed? Shut off water, loosen C-5 and adjust the pivot to lower the plunger. Retighten the bolt.

After reassembly, turn the water back on. Open and close the hydrant after each adjustment. Check that the spout stops flowing and the standpipe drains with the hose removed.