SP PITLESS UNIT INSTALLATION GUIDE

Simple step-by-step installation & removal

SP pitless unit casing with side outlet
SP UNIT CASING
SP pitless internal assembly with support plate, adjusting rod and sealing elbow
INTERNAL ASSEMBLY

TOOLS & MATERIALS

2 PIPE WRENCHES

For threading drop pipe into the sealing elbow.

ANTI-SEIZE / GASKET LUBE

Use on the O-ring, guide plate slots and edges.

PUMP PULLING RIG OR LIFTING DEVICE

For lowering and lifting the casing, pipe and pump assembly.

Provides a sanitary, below-ground water connection while providing easy pump removal for future service.

The SP Pitless Unit is built with noncorrosive construction for long-lasting operation and future service.

RELIABLE SEALING

Proven sealing design. Eliminates pressure damage to seal points for future service.

EASY SERVICE

Stainless steel nut allows quick and easy pump removal for maintenance.

BUILT TO LAST

Stainless steel components engineered for decades of reliable service.

Installation Instructions

1Prepare & Install Unit Casing

REMOVE THE INSIDE ASSEMBLY

Remove the inside assembly from the pitless unit casing.

ATTACH THE UNIT CASING

Attach the unit casing to the well casing at the depth required for the water lines below frost depth.

MAINTAIN VERTICAL ALIGNMENT

Merrill pipe connectors can simplify the attachment and help keep the casing aligned.

Inside assembly removed from casing
Inside assembly removed from casing
Unit casing attached to well casing
Unit casing attached to well casing
Important: Check Vertical AlignmentConfirm casing depth and alignment before proceeding to Step 2.

2Apply Anti-Seize / Gasket Lube

Lubricate the O-ring and guide plate slots and edges. Use Merrill PAL100 or equivalent compatible lubricant. Proper lubrication improves sealing, prevents sticking and makes service easier.

3Thread Drop Pipe into Sealing Elbow

Drop pipe connection diagram and tightening instructions. Use a pipe wrench on the drop pipe and sealing elbow; do not wrench on other parts of the assembly.

4Lower Assembly

Lower the assembly slowly and keep it aligned.

5Align Support Plate

Fit the support plate rib into the unit casing notch to assure the positive sealing position.

6Engage Seal

Turn the adjusting nut counter-clockwise all the way until rod threads are fully down. Move the plate flush with the casing. The seal is now engaged.

Removal Instructions

Follow Steps 7 and 8 to properly disengage the seal and pull the inside assembly for service.

7Disengage Seal

Turn the adjusting nut clockwise all the way until rod threads are fully up. The seal is disengaged.

8Pull Assembly

Lift the internal assembly for service after disengaging the seal.