SSMCU Pitless Unit
Installation Guide
For Merrill SSMCU pitless units — 4", 5" and 6" models
Match the unit size, bury depth and discharge connection before starting.
Before you start
Check unit & components
Confirm casing diameter, bury depth, discharge size, support bar, O-ring and the correct watertight cap.
Make the site safe
Shut off and verify pump power. Keep dirt out of the well and use rated equipment to support the pump.
Installation | Steps 1–4
Make the adjustment tool
Cut 1/2-inch pipe to the length in the chart below. Flatten one end to fit the stainless screw inside the pitless body.
Attach the drop pipe
Thread the pump pipe into the stainless pitless body. Put wrenches on the pipe and body — NOT the upper pull pipe.
Lubricate & lower
Apply Anti-Seize/Gasket Lube to the O-ring seal. With the pump safely supported, lower the assembly into the casing.
Line up the support bar
As you lower the assembly, align the mark on the support bar with the notch or mark at the top of the casing.
DangerDisconnect and verify pump power; support the pump and drop-pipe weight. Protect the open well.
ImportantUse wrenches on the pipe and stainless pitless body, never on the included pull pipe above it.
Finish installation | Steps 5–6
Check before sealing
Keep the pump supported. Confirm the support-bar mark is aligned and the O-ring is lubricated.
Seal & close the well
Engage the O-ring seal
Use the custom wrench to turn the stainless screw CLOCKWISE until the O-ring seals against the inside of the casing.
Install the watertight cap
Install the required watertight cap on top of the well casing. The cap model must meet applicable state well code.
For future pump removal | Steps 7–8
Release the seal
Before pulling the pump, turn the stainless screw COUNTERCLOCKWISE so the back lever can pivot inward.
Connect to support bar & lift
Connect approved lifting equipment to the center threads of the support bar, then lift while supporting the load.
DangerNever lift an unsupported pump. Have qualified well personnel handle lifting and electrical work.
ImportantCLOCKWISE seals; COUNTERCLOCKWISE releases. Check the cap, O-ring seal and connections before use.