TORQUE ARRESTORINSTALLATION GUIDE

For submersible well pumps

Less twist. Better pump protection.

Helps stabilize the drop pipe and reduce pump movement during pump starts and stops.

Before You Start

Check Fit & Parts

Fits 1" or 1-1/4" drop pipe and 4"–8" casing. STA48C and STA48CI include stainless steel clamps; STA48 requires two suitable clamps.

Power & Safety

Switch off and lock out pump power; verify it is off. Have a nut driver, gloves and suitable equipment to support the pump and pipe.

4 Simple Steps

  1. Position the Arrestor

    Place the first arrestor no more than 3 ft above the pump. Fit both halves evenly around the drop pipe.

  2. Secure the Lower Clamp

    Tighten the lower stainless steel clamp. Position the upper clamp but leave it loose for adjustment.

  3. Adjust to the Casing

    Push down on the top of the arrestor to expand the middle. Set a snug fit inside the casing - never a tight or forced fit.

  4. Tighten & Verify

    Secure the upper clamp firmly. Keep pump wiring clear, check that nothing snags, and add arrestors every 100 ft if needed.